Hoppa till innehåll
Gratis fragt over 3.000 kr. ekskl. moms! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference FurnaceVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference Furnace
Item number 65-142315243

0-1500 mm aluminum vernier caliper, 0.001 mm resolution, microprocessor, 0.001 mm resolution

Call for price

In stock
Request a quote 65-142315243
  • Gratis fragt over 3.000 kr. ekskl. moms
  • Hand-held and bench measuring equipment from Mahr

Category:

Description

Digital vernier caliper with measuring range 0-1500 mm, 0.001 mm resolution, wireless data output, touchscreen, extensive software functions

Accurate reading of measurement results with a resolution of 0.001 mm. High measurement reliability with 0.04 mm accuracy. A microcomputer with a touchscreen is installed for displaying the vernier caliper, via which the software functions can be accessed. The unit has a measuring force regulation, which is 8 N. The measuring force regulation ensures that a maximum measuring force is always applied. This leads to more accurate and better measurement results. A handcrafted measuring jaw ensures high precision. The unit uses a rechargeable battery. This eliminates the need for constant battery replacement. The measuring tool is delivered including a calibration certificate according to ISO 17025.

MICS Microcomputer System – Industry 4.0 ready!!

Microtech’s innovative computer-aided MICS system takes measuring equipment to the next level. The system is equipped with a touchscreen and many software functions and leaves no room for alternatives.

The display is via a clearly readable touchscreen. An ergonomic menu ensures easy menu navigation. Up to 100 measured values can be stored via the internal memory. The statistics can be used to retrieve min, max and average values.

The resolution with the MICS system can be up to 0.0001 mm. GO/NoGO values can be displayed in color (green for GO / red for NoGO). Reading of MIN/MAX VALUES. The form mode makes it possible to enter calculation formulas with corresponding evaluation. Ambient temperatures can be incorporated into the measurement result via temperature compensation for 7 different materials. Mathematical error corrections can be incorporated easily and quickly. The display can be rotated in all directions, depending on the working direction. The calibration date can be stored in the software, so you do not always have to look at the computer when a new calibration must be performed. The wireless data transfer can be triggered via a timer, via the touchscreen or with the button.

For the measuring tools with the MICS system, there is free basic software for Windows, Android and iOS. Extended functionality can be achieved via a paid update.

The MICS software in detail:

  • Go/NoGo (with color coding)
  • Max/min,
  • Storage for up to 100 measured values.
  • Statistics,
  • Timer,
  • Formulas,
  • mm/inch,
  • Pre-setting function,
  • Calibration date,
  • Lock
  • Mathematical and temperature compensation
  • Switch off
  • Brightness
  • Rotation,
  • Rechargeable Li-Po battery

Technical data:

  • Manufacturer: Microtech
  • Order number: 142315243
  • Product: Vernier caliper
  • Measuring range: 0-1500
  • Resolution: 0.001 mm
  • Data output: Wireless
  • with touchscreen
  • MICS system with extensive software functions
  • Accuracy: 0.04 mm
  • Measurement of pressure regulation with 8 N
  • Including calibration certificate according to ISO 17025
  • Design: digital
  • Handmade measuring jaws
  • with microcomputer and extensive software
  • Rechargeable battery
  • Length of measuring tip at the bottom: 200 mm
  • Weight: 5.2 kg
  • Material: aluminium