Published 16 November 2026 at 00:20
Monday morning, the refrigerator in the laboratory or the cold room in production shows the correct temperature. But what was the temperature on Sunday night? If the compressor failed for six hours and managed to get back to temperature, nobody knows until the samples or goods have been used, and then the question is what it costs. A handheld thermometer reading once a day will not catch that kind of thing.
What is the ETI ThermaData WiFi TD2TC
It is a battery-powered temperature logger with two channels for external type K or T thermocouple probes. The logger records the temperature at a selectable interval and sends the data via WiFi to a router with an internet connection. You can then view the curves from a computer or tablet, wherever you are. The resolution is 0.1 °C up to 999.9 °C, and the memory holds up to 18,000 readings, corresponding to 9,000 per probe. Note that the probes are supplied separately, so you choose them according to the task.
What problems does it solve
It solves two things. First, it closes the gap between manual measurements, so a deviation is recorded while it is happening. Second, you can program a high and a low alarm limit, so you are notified before the damage is done. On the logger’s own display you can see the current temperature, min. and max. values, alarm status, WiFi connection and battery condition. This is useful when you are standing in front of the equipment and want the answer immediately. The range depends on your WiFi router, so the placement must be planned.
Three concrete situations
Food production: One probe in the cold room and one in the freezer provide documentation for your self-inspection program and an alarm if a door is left open after closing time. Type T is well suited to low temperatures.
Laboratory: Incubators, sample cabinets and refrigerators require a traceable temperature history. The logger is supplied with a traceable calibration certificate, which can be included directly in the quality system.
Plumbing and installation: Two channels make it possible to measure flow and return temperature simultaneously and follow the progression over the course of a day, for example when troubleshooting a heat pump or a circulation system where the fault only occurs under certain operating conditions.
Why it pays off
The calculation is simple. A single batch of goods or a set of samples that has to be discarded after an undetected temperature deviation often costs more than the logger. Added to this is the time saved by avoiding fixed inspection rounds, and the hours spent reconstructing what happened when an auditor or a customer asks. With data on the screen, the answer becomes a graph rather than an estimate. Two channels in one unit also means fewer units to maintain and calibrate.
If you want to see the specifications and choose the right probes for your task, you will find the logger here.