Hoppa till innehåll
Gratis fragt over 3.000 kr. ekskl. moms! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference FurnaceThe caliper read five hundredths of a millimetre too high for three weeks, and nobody noticedWhen it’s the tolerance, not the number, that counts: how to read serial parts in a secondWhen the spirit level says flat, but the machine still runs crooked: angle measurement with 0.05° resolutionVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference FurnaceThe caliper read five hundredths of a millimetre too high for three weeks, and nobody noticedWhen it’s the tolerance, not the number, that counts: how to read serial parts in a secondWhen the spirit level says flat, but the machine still runs crooked: angle measurement with 0.05° resolution
Item number 56-TR72A2

TandD Logger for temperature and humidity, external sensors, wireless WiFi LAN + Bluetooth. 0–55 °C, 10–95 %RH. Cloud connection

2.102 DKK

In stock

TandD Logger for temperature and humidity, external sensors, wireless WiFi LAN + Bluetooth. 0–55 °C, 10–95 %RH. Cloud connectivity

Request a quote 56-TR72A2

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Gratis fragt over 3.000 kr. ekskl. moms
  • Hand-held and bench measuring equipment from Mahr

Category: , , , ,

Other models in the series 16

Description

The 56-TR72A2 is TandD’s WiFi-connected temperature and humidity logger — it connects directly to your WiFi network and automatically uploads measurement data via encrypted HTTPS to the T&D WebStorage cloud. No separate base unit is required.

An external T/RH probe on a cable is included. The measuring range of 0–55 °C and 10–95 %RH covers most indoor environments. Advanced WPA2-Enterprise support (IEEE 802.1X with EAP-TLS/PEAP) makes the device compatible with corporate networks. Email + push notification alerts are configured directly in the web interface of the T&D WebStorage Service.

Features

  • External T/RH probe on cable (included)
  • Temperature measuring range: 0 to +55 °C
  • Humidity measuring range: 10 to 95 %RH
  • Accuracy ±0.5 °C / ±5 %RH (at 25 °C, 50 %RH)
  • WiFi 802.11 b/g/n (2.4 GHz) with WPA-PSK/WPA2-PSK/WPA2-Enterprise
  • HTTPS for secure data upload
  • 30,000 data point memory (combined temp + RH)
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • 15 selectable upload intervals: 1 min to 24 hours
  • Bluetooth 4.2 BLE for configuration via T&D Thermo app
  • USB 2.0 Mini-B for PC connection
  • Email alerts via T&D WebStorage Service
  • LCD displaying current values + Max/Min

Specification

Measurement channels Temperature 1 channel (thermistor) + Humidity 1 channel (polymer) — external, on cable
Measurement range 0 to +55 °C / 10 to 95 %RH
Accuracy ±0.5 °C / ±5 %RH (at 25 °C, 50 %RH)
Resolution 0.1 °C / 1 %RH
Response time (90 %) approx. 7 minutes
Logging capacity 30,000 data points
WiFi IEEE 802.11 b/g/n (2.4 GHz)
Security WPA-PSK / WPA2-PSK / WPA2-Enterprise, WPS 2.0
Protocols HTTP, HTTPS, SNTP, DHCP, DNS
Other interfaces Bluetooth 4.2 BLE, USB 2.0 Mini-B
Power supply 2 × AA alkaline LR6, 2 × AA Ni-MH, USB bus, AC adapter 56-AD-05A2/C2
Battery life approx. 5 days (at 1 min logging interval)

Applications

The 56-TR72A2 is suitable for T/RH monitoring in environments with WiFi access: offices, data centers, laboratories, retail stores, food storage, museums/archives, greenhouses, and wine cellars. For 2-channel temperature measurement without RH, see 56-TR71A2. For high precision (±2.5 %RH), see 56-TR72A2-S. For wired Ethernet, see 56-TR-72NW.

Additional information
Product Type

Data Logger

Measures

% Relative Humidity, Temperature

Communication

Wireless Bluetooth, Wireless WiFi