Hoppa till innehåll
Gratis fragt over 3.000 kr. ekskl. moms! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference FurnaceVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference Furnace
Item number 64-536161

Mitutoyo analog special vernier caliper for pipe stock 150 mm, 0-150 mm, vernier 0.05 mm

3.661 DKK

In stock

Precision tools for accurate measurements. This vernier caliper with a 150mm measuring range delivers exact results for both internal and external dimensions. Perfect for professional technicians and hobby mechanics who require reliable measurements. Robust construction ensures long service life and consistent precision.

Request a quote 64-536161

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Gratis fragt over 3.000 kr. ekskl. moms
  • Hand-held and bench measuring equipment from Mahr

Category:

Description

Mitutoyo vernier caliper for pipe wall thickness measurements, 0-150 mm, reading 0.05 mm is the specialized vernier caliper for measuring pipe wall thickness in a single pickup — one jaw enters the pipe from the open end, the other jaw rests against the outside diameter at the same axial position, and the reading is the wall thickness directly. The geometry eliminates the most common error in pipe wall measurement: attempting to derive wall thickness from separate ID and OD readings on a standard vernier caliper.

The jaw geometry is the design difference. The lower jaw is a fixed-position contact that sits against the OD; the upper jaw is shaped as a hook or pin that reaches over the pipe end and sits inside the hollow wall on the same side. With both jaws in contact, the gap between them is exactly the wall thickness at that point. Operators rotate the pipe under the jaws to sample wall thickness at multiple clock positions, which finds the thinnest section — the critical dimension for pressure vessel and structural pipe acceptance.

The vernier reading at 0.05 mm is the shop-grade mechanical scale suitable for pipe shop and fabrication work. For tighter wall thickness measurement, an ultrasonic wall thickness gauge is the right step up — it does not require open-end access. The mechanical vernier caliper remains the right tool when access is available and tolerance is within the shop band.

Common applications: pressure vessel pipe wall acceptance during incoming inspection, structural pipe wall measurement during fabrication, hydraulic cylinder pipe wall verification during overhaul, and any pipe end inspection where wall thickness is the critical dimension.

Features

  • Mitutoyo vernier caliper for pipe wall thickness measurements
  • Range 0-150 mm, reading 0.05 mm
  • Single-pickup wall thickness — no separate ID/OD reading + subtraction
  • Hook/pin upper jaw sits inside the hole from the pipe end
  • Vernier mechanical reading — no power dependency
  • Shop-grade accuracy class

Specifications

Manufacturer Mitutoyo
Type Vernier caliper for pipe wall thickness
Range 0-150 mm
Reading 0.05 mm
Reading type Vernier (mechanical)
Item number 64-536161

Compatible accessories

Mitutoyo vernier caliper inspection sets (items 64-516124, 64-516526) for full standard delivery calibration. Mitutoyo gauge block reference sets (sold separately) for periodic verification.

Additional information
Weight 0,149 kg
Measuring range

0-150 mm

Readout
Type

vernier

Variants

64-536161,64-573662

Variant Properties

range,read_out,type

Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.