Hoppa till innehåll
Gratis fragt over 3.000 kr. ekskl. moms! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference FurnaceVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference Furnace
Item number 65-142115182

0-1500mm vernier caliper in aluminium, 0.001mm resolution, long measuring jaws, microprocessor,

Call for price

In stock
Request a quote 65-142115182
  • Gratis fragt over 3.000 kr. ekskl. moms
  • Hand-held and bench measuring equipment from Mahr

Category:

Description

Digital vernier caliper with measuring range 0-1500mm, 0.01mm resolution, wireless data output, touchscreen input, extensive software functions

Accurate reading of measured values with a resolution of 0.01 mm. High measurement reliability with 0.085 mm accuracy. Instead of a standard screen, a microcomputer with a touchscreen is installed. Extensive software functions are available. The unit features a measuring force control of 8 N. The measuring force control ensures that a maximum measuring force is always applied, leading to a more accurate measurement result. Handcrafted measuring jaws ensure high precision. The unit has a rechargeable battery. This eliminates the need for constant battery replacement. Delivered with a calibration certificate according to ISO 17025.

MICS Microcomputer System – Industry 4.0 ready!!

Microtech’s groundbreaking computer-supported MICS system takes the vernier caliper to the next level. The system is equipped with a touchscreen and many software functions, leaving little to be desired.

The display is via a touchscreen. A user-friendly menu ensures simple menu navigation. Up to 100 measured values can be stored via internal memory. Statistics can be used to retrieve min, max, and average values.

The resolution with the MICS system can be up to 0.0001 mm. GO/NoGO values can be displayed in color (green for GO / red for NoGO). Reading of MIN/MAX values. The formula mode makes it possible to enter calculation formulas with corresponding evaluation. Ambient temperatures can be incorporated into the measurement result via temperature compensation for 7 different materials. For certain measurements, it is necessary to include a mathematical error correction, which is also possible with the microcomputer system. Depending on the working direction, the display can be rotated. The calibration date can be integrated into the software; an external date search is not necessary. The wireless data transfer can be triggered via a timer, touchscreen, or button.

Measuring tools with the MICS system are delivered with free basic software for Windows, Android, and iOS. Extended functionality can be achieved via a paid update.

MICS software in detail:

  • Go/NoGo (with color coding)
  • Max/min,
  • Storage for up to 100 measured values.
  • Statistics,
  • Timer,
  • Formulas,
  • mm/inch,
  • Pre-set function,
  • Calibration date,
  • Lock
  • Mathematical and temperature compensation
  • Switch off
  • Brightness
  • Rotation,
  • Rechargeable Li-Po battery

Technical data:

  • Manufacturer: Microtech
  • Order number: 142115182
  • Product: Vernier caliper
  • Measuring range: 0-1500
  • Resolution: 0.01 mm
  • Data output: Wireless
  • with touchscreen
  • MICS system with extensive software functions
  • Accuracy: 0.085 mm
  • Measurement of pressure regulation with 8 N
  • Including calibration certificate according to ISO 17025
  • Design: digital
  • Handmade measuring jaws
  • with microcomputer and extensive software
  • Rechargeable battery
  • Length of measuring tip at the bottom: 800mm
  • Weight: 20 kg
  • Material: aluminium

Aluminium was used as the material. The advantage is that the instrument is extremely stable and very light.