Hoppa till innehåll
Gratis fragt over 3.000 kr. ekskl. moms! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference FurnaceThe caliper read five hundredths of a millimetre too high for three weeks, and nobody noticedWhen it’s the tolerance, not the number, that counts: how to read serial parts in a secondWhen the spirit level says flat, but the machine still runs crooked: angle measurement with 0.05° resolutionVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Three Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleThe Surface Doesn’t Tell the Whole Story: Get Both Non-Contact and Contact Measurement in One InstrumentHow to Check Your K-Type Thermometer in a Few Minutes Without an Ice Bath or Reference FurnaceThe caliper read five hundredths of a millimetre too high for three weeks, and nobody noticedWhen it’s the tolerance, not the number, that counts: how to read serial parts in a secondWhen the spirit level says flat, but the machine still runs crooked: angle measurement with 0.05° resolution
Item number 56-TR-73U

TandD Handheld Logger for Temperature, Humidity and Atmospheric Pressure (3 Channels). LCD Display, USB

2.582 DKK

In stock

TandD Handheld logger for temperature, humidity, and atmospheric pressure (3 channels). LCD display, USB

Request a quote 56-TR-73U

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Gratis fragt over 3.000 kr. ekskl. moms
  • Hand-held and bench measuring equipment from Mahr

Category: , , , , , ,

Other models in the series 6

Description

The 56-TR-73U is TandD’s 3-channel handheld logger that measures temperature, humidity AND atmospheric pressure simultaneously in a single unit — perfect for weather documentation, calibration measurements, and quality control where all three parameters are required at the same time.

The included TR-3100 T/RH probe provides 0–55 °C / 10–95 %RH with ±0,3 °C accuracy in the calibration range of 0–50 °C. The built-in barometer measures 750–1100 hPa with ±1,5 hPa accuracy. The logger is approved according to RTCA DO-160E Section 21 for radio frequency emission — meaning it can be carried on board flights as carry-on luggage and used during flight without interfering with avionics. Highly useful for air freight documentation of temperature-sensitive cargo.

Features

  • 3 channels: temperature, humidity and atmospheric pressure
  • Temp/RH with external TR-3100 probe: 0 to +55 °C / 10 to 95 %RH
  • Atmospheric pressure (internal sensor): 750 to 1100 hPa
  • Accuracy T: ±0,3 °C (0–50 °C) / ±0,5 °C / ±1,5 hPa
  • Resolution 0,1 °C / 1 %RH / 0,1 hPa
  • Direct USB 2.0 Mini-B connection to PC
  • 8,000 data point memory (combined for all 3 channels)
  • 15 fixed logging intervals: 1–60 sec or 1–60 min
  • RTCA DO-160E Section 21 approved — can be used in the aircraft cabin
  • Powered by 1 × AA battery for approx. 10 months
  • Front buttons for start/stop, interval selection, display selection
  • Built-in LCD with rotation of all values
  • Specification

    Measuring channels Temperature 1 channel (external TR-3100) + Humidity 1 channel (external) + Atmospheric pressure 1 channel (internal)
    Measuring range T (included probe) 0 to +55 °C, optional: -40 to +110 °C
    Measuring range RH 10 to 95 %RH
    Measuring range pressure 750 to 1100 hPa
    Accuracy ±0.3 °C (0–50 °C, calibration) / ±5 %RH / ±1.5 hPa
    Resolution 0.1 °C / 1 %RH / 0.1 hPa
    Response time (90 %) T/RH: approx. 7 min; Pressure: 4 sec (1 sec interval) or 40 sec (≥10 sec interval)
    Logging capacity 8,000 data points
    Communication USB 2.0 Mini-B, serial (via optional cable 56-TR-07C)
    Power supply 1 × AA alkaline LR6 (included)
    Battery life approx. 10 months
    Dimensions 55 × 78 × 18 mm
    Weight approx. 40 g
    Operating environment -10 to +60 °C, max 90 % RH non-condensing
    Certificates RTCA DO-160E Section 21 (airborne radio emission)

    Included

    • 56-TR-73U logger
    • 1 × AA alkaline battery
    • External T/RH probe 56-TR-3100
    • USB Mini-B cable 56-US-15C
    • Manual set with warranty certificate

    Applications

    The 56-TR-73U is selected for applications where atmospheric pressure is critical: air transport of temperature-sensitive products (pharmaceuticals, biochemical samples, sensitive electronic components), weather documentation, calibration tasks requiring pressure-compensated T/RH values, high-altitude measurements, dive centers, and vehicle testing centers. For simpler T/RH without pressure, see 56-TR-72NW (Ethernet) or 56-TR72A2 (WiFi).

    Additional information
    Product Type

    Data Logger

    Measures

    % Relative Humidity, Atmospheric Pressure, Temperature

    Communication

    Wired USB

    PDF (1)