Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the thermometer reads 3.0 °C but the product is at 5.5 °C: how to check your thermocouples at three pointsThe temperature was fine at the inspection, but what happened overnight?Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handleVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%When the thermometer reads 3.0 °C but the product is at 5.5 °C: how to check your thermocouples at three pointsThe temperature was fine at the inspection, but what happened overnight?Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CThe temperature failed at three in the morning: How to spot it while there is still time to actThe surface doesn’t always tell you what’s happening inside: two temperature measurements in one handle

When the thermometer reads 3.0 °C but the product is at 5.5 °C: how to check your thermocouples at three points

Published 22 November 2026 at 17:01

Most people have experienced it: two handheld thermometers in the same cold room show different readings. One says 2.8 °C, the other 4.1 °C. Nobody knows which one is right, and nobody knows how long the deviation has existed. That means the temperatures recorded in your self-monitoring log are, in practice, a guess.

ETI MicroCheck® calibrated temperature simulator, K-type, -20 °C, 0 °C & +100 °C, incl. calibration certificate & protective holster

What the ETI MicroCheck is

The MicroCheck is a small handheld checking device that electrically simulates three fixed temperatures. In this version, the points are -20 °C, 0 °C and +100 °C. You connect your type K thermometer via the included one-metre thermocouple lead with miniature connector and read what the instrument displays at each point. The device has a 10 mm LCD display, and you can choose °C/°F, automatic shut-off and internal or external CJC. It measures 35 x 73 x 141 mm, weighs 175 g and runs on two AAA batteries for about 300 hours.

The problem it solves

A thermocouple thermometer specified at ±0.5 °C is only as good as its last check. Shocks, cable damage and electronic drift happen gradually. Normally, a check requires an ice bath, a dry-block calibrator or shipping to a laboratory. The MicroCheck turns it into a task of a few minutes at your desk or on the production floor.

Each unit is supplied with a three-point UKAS calibration certificate stating the deviation at each point. This gives you a traceable reference point when you document the check. Please note that the delivery time is 10-14 days, because the unit is calibrated to order.

Where it is used in practice

In food production and commercial kitchens, thermometers for cold rooms and freezers are checked at 0 °C and -20 °C, while 100 °C suits cooking temperatures. These are exactly the points an HACCP auditor asks about.

In a laboratory or cold chain, you can check the handheld thermometers used for spot checks before a deviation turns into the rejection of an entire delivery.

In maintenance and process plants, type K is used for heat exchangers, ovens and piping systems. Here you check the instrument before troubleshooting, so you can be sure it is the plant and not the meter that is deviating.

Why it pays off

The calculation is simple. A thermometer reading two degrees too low in a cold room can cost an entire pallet of goods if it is discovered too late. Conversely, a thermometer reading too high can lead to food being thrown away that was perfectly fine. Add to that the time and transport costs of sending each instrument out for periodic calibration. With the MicroCheck, the interval between external calibrations can be used in a more targeted way, and you can check all thermometers weekly or monthly without additional equipment. Remember, however, that a check does not replace an accredited calibration when a customer or a set of regulations requires one.

The unit is supplied with a protective holster and a two-year warranty.