Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The temperature in your process is rarely the one you read: How to get a measuring point you can trustA 35.00 mm hole can easily be oval: how to find the form error the caliper missesWhen the thermometer reads 3.0 °C but the product is at 5.5 °C: how to check your thermocouples at three pointsThe temperature was fine at the inspection, but what happened overnight?Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °CVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The temperature in your process is rarely the one you read: How to get a measuring point you can trustA 35.00 mm hole can easily be oval: how to find the form error the caliper missesWhen the thermometer reads 3.0 °C but the product is at 5.5 °C: how to check your thermocouples at three pointsThe temperature was fine at the inspection, but what happened overnight?Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentHow much do your thermometers actually deviate? Find out with ±0.03 °C
Item number 17-271100

ETI MicroCal® 1 Calibrated Temperature Simulator, Simulates Type K, J, T, R, N, S & E Temperature Sensors. With Calibration Certificate

1.853 DKK

In stock

MicroCal 1 thermocouple simulator.

12 adjustable temperature points
Enables frequent checks of thermometer accuracy
Tests thermocouple type K, J, T, R, N, S & E thermometers
5-point UKAS calibration certificate included
Delivery within 10-14 days, the product is calibrated at the time of purchase

Not available for next-day delivery as certified at the time of order

Request a quote 17-271100

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Gratis fragt over 3.000 kr. ekskl. moms
  • Hand-held and bench measuring equipment from Mahr

Category:

Other models in the series 16

Description

The MicroCal 1 thermocouple simulator helps ensure that frequent checks of thermometer accuracy are a routine operation. The calibrator is designed to simulate a chosen temperature to test type K, J, T, R, N, S, and E thermocouple thermometers without the need for specialized equipment or conversion tables. The MicroCal 1 Plus calibrator also measures and simulates temperature.
The MicroCal 1 features a custom 10 mm LCD display with an alphanumeric display line to prompt the user when changing parameters. Selectable parameters include: °C/°F, auto-power off – enable/disable, CJC – internal/external, and display contrast adjustment.
An optional lead set is also available, comprising seven leads, one for each thermocouple type K, J, T, R, N, S, and E. Each PVC lead is one meter long and fitted with two miniature thermocouple plugs.
Each MicroCal is supplied with a one-meter PVC type K thermocouple lead with miniature connectors and a five-point (type K) UKAS calibration certificate indicating deviations from standards at the various points.
Type K thermocouple – range -200 to 1372°C Type J thermocouple – range -200 to 1200°C Type T thermocouple – range -270 to 400°C Type R thermocouple – range 0 to 1768°C Type N thermocouple – range -200 to 1300°C Type S thermocouple – range 0 to 1768°C Type E thermocouple – range -140 to 1000°C
All thermocouple types are based on BS EN 60584-2:1993

Specifications

Measuring range: see "More info" tab
Temperature points: 12 adjustable presets
Accuracy: ±0.3 °C (depending on thermocouple type)
Battery: 2 x 1.5 volt AAA
Battery life: 300 hours
Sensor type: Thermocouple (selectable: type K, J, T, R, N, S, and E)
Dimensions: 35 x 73 x 141 mm
Weight: 175 grams
Casing material: ABS plastic
Country of manufacture: United Kingdom
Warranty: two years
Measurement scale: Celsius/Fahrenheit
Certification: UKAS calibration certificate
Additional information
Product Type

Kalibrator

Tilbehør Beskyttelse & Opbevaring

17-830205,17-832115

Tilbehør Følere

17-816100

Trådløs

Nej

PDF (2)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *

Tilbehør Følere

ETI Cable Set for Thermometer Calibration with Calibrator. It is important to use the correct cable; the cable set includes cables for types K, J, T, R/S, N, and E.
17-816100
786 DKK
Lägg i varukorgen

Tilbehør Beskyttelse & Opbevaring

ETI PVC Protective Sleeve for Thermometers in the MicroTherma® Series
17-830205
87 DKK
Lägg i varukorgen
ETI Wall Mount for ETI MicroCal and MicroCheck Thermometers
17-832115
100 DKK
Lägg i varukorgen