Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Core temperature determines whether your self-monitoring holds up, not a gut feeling in the kitchenThe temperature in your process is rarely the one you read: How to get a measuring point you can trustA 35.00 mm hole can easily be oval: how to find the form error the caliper missesWhen the thermometer reads 3.0 °C but the product is at 5.5 °C: how to check your thermocouples at three pointsThe temperature was fine at the inspection, but what happened overnight?Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Core temperature determines whether your self-monitoring holds up, not a gut feeling in the kitchenThe temperature in your process is rarely the one you read: How to get a measuring point you can trustA 35.00 mm hole can easily be oval: how to find the form error the caliper missesWhen the thermometer reads 3.0 °C but the product is at 5.5 °C: how to check your thermocouples at three pointsThe temperature was fine at the inspection, but what happened overnight?Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistent
Item number 17-813525

ETI TDS1 ppm conductivity meter. Measures ppm (parts per million). Resolution 10ppm, range 10-1990

816 DKK

In stock

TDS Conductivity Tester

  • Genuinely pocket-sized
  • Easy-to-read 6 mm LCD display
  • Indicates ppm (parts per million) or µS (micro-siemens)
  • Accuracy of ±2% of full scale
Documents:813 525 C of C
Request a quote 17-813525

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Gratis fragt over 3.000 kr. ekskl. moms
  • Hand-held and bench measuring equipment from Mahr

Category:

Description

These TDS conductivity meters provide the perfect solution for measuring ppm or μS. The TDS meters are ideal for monitoring a wide range of applications, including the amount of salts or dissolved solids in water. Readings are automatically temperature-compensated in the range of 0 to 50 °C.

There are two models of both TDS and conductivity meters, suitable for either low or high concentrations of total dissolved solids in liquids.

Conductivity Electrode Maintenance

The ETI range of conductivity meters includes TDS meters, nutrient meters, salt concentration meters, and WalkLAB Pro conductivity meters.

Various calibration solutions are available for regular calibration of the instruments.

Storage: It is best to store cells with the electrodes immersed in deionized water. All cells that have been stored dry should be soaked in distilled water for 5 to 10 minutes before use to ensure complete wetting of the electrodes.

The single most important requirement for accurate and reproducible results in conductivity measurement is a clean cell. A dirty cell will contaminate the solution and cause the conductivity to change. Grease, oil, fingerprints, and other contaminants on the sensing elements can cause erroneous measurements and sporadic reactions.

Electrodes can be cleaned with a mixture of 1 volume part isopropyl alcohol, 1 part ethyl ether, and 1 part HCl (1+1). After cleaning, rinse the cell thoroughly with water. If the old platinum black coating needs to be removed, it is often successful to apply aqua regia to the electrodes, or perform electrolysis in HCl. This should only be attempted by trained operators.

Electrodes can also be cleaned with detergents and/or nitric acid (1%) by dipping or filling the cell with the cleaning solution and stirring for two or three minutes.


Rinse the cell several times with distilled or deionized water and measure the cell constant before use.

Range: TDS1: 10-1990, TDS2: 100-9999, COND3: 10-1990, COND4: 100-19900
Resolution: TDS1: 10 ppm, TDS2: 100 ppm, COND3: 10µS, COND4: 100µS
Accuracy: ±2% of full scale
Battery: 4 x 1.5 volt LR44 button cell
Battery life: 100 hours
Display: 6 mm LCD
Dimensions: 15 x 32 x 147 mm
Weight: 70 grams
Packaging material: ABS plastic
Warranty: one year
Water/dust resistance: waterproof
Measurement scale: ppm (TDS1 & TDS2) or µS (COND3 & COND4)