Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Core temperature determines whether your self-monitoring holds up, not a gut feeling in the kitchenThe temperature in your process is rarely the one you read: How to get a measuring point you can trustA 35.00 mm hole can easily be oval: how to find the form error the caliper missesWhen the thermometer reads 3.0 °C but the product is at 5.5 °C: how to check your thermocouples at three pointsThe temperature was fine at the inspection, but what happened overnight?Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistentVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Core temperature determines whether your self-monitoring holds up, not a gut feeling in the kitchenThe temperature in your process is rarely the one you read: How to get a measuring point you can trustA 35.00 mm hole can easily be oval: how to find the form error the caliper missesWhen the thermometer reads 3.0 °C but the product is at 5.5 °C: how to check your thermocouples at three pointsThe temperature was fine at the inspection, but what happened overnight?Air Temperature Is Not Product Temperature: How to Monitor a Refrigerator So the Reading Can Be TrustedSee the fault inside the pipe before you tear up the floor: 30-meter camera probe for pipes and hidden cavitiesThe Caliper That Doesn’t Lose Its Zero Point When Coolant Hits ItThree Seconds Instead of Twenty: How a Fast Probe Thermometer Changes Self-Monitoring in the KitchenWhen the caliper itself shows go or no-go, sampling inspection becomes faster and more consistent

ISO 286-2 Tolerance Table up to 500 mm: When the H7/g6 Notation on a Drawing Isn’t Just “Loose Fit” but EXACTLY +25/-9 μm on Ø30 mm, and the Toolmaker Has to Look It Up in a 60-Page Table

Published July 15, 2026 at 7:42 PM

Engineering science standardizes its language to AVOID misunderstandings that can cause mechanical failures. One of the most fundamental standardizations is ISO 286 — the international standard for dimensions and tolerances for LINEAR SIZES such as holes and shafts.

ISO 286 is divided into two parts:

  • ISO 286-1: The base standard that DEFINES the system for tolerances and fits.
  • ISO 286-2 (this table): TABLES of standard tolerances for holes and shafts, up to a nominal diameter of 500 mm.

This table is the DAILY LOOKUP REFERENCE for all toolmakers, designers, QC inspectors and machine maintenance technicians.

Basic ISO 286 notation

ISO 286 uses a coding system like H7 or g6:

  • Letter: Indicates the POSITION of the tolerance zone relative to the nominal dimension.
    • UPPERCASE letters (A, B, …, H, …, Z): for HOLES (bore, hole).
    • Lowercase letters (a, b, …, h, …, z): for SHAFTS (shaft).
  • Number: Indicates the WIDTH of the tolerance zone (tolerance grade).
    • IT01, IT0 (very tight): for measuring-tool manufacturing.
    • IT1-IT5: precision mechanics.
    • IT6-IT10: general mechanics (most common in manufacturing).
    • IT11-IT18: coarse mechanics, construction work.

Common FIT CATEGORIES

A HOLE + a SHAFT form a FIT. Combinations are classified into three categories:

Clearance fit (running fit): The shaft can rotate freely in the hole. Standard notation H7/g6 or H7/f7. Clearance ~10-50 μm depending on diameter.

Transition fit: The shaft fits SNUGLY — requires careful assembly but can be disassembled. Standard H7/k6 or H7/j7. Clearance can be positive (loose) or negative (interference).

Interference fit: The shaft is LARGER than the hole. Must be PRESS-fitted or heat-shrunk together. Standard H7/p6, H7/r6, H7/s6. Interference 20-150 μm.

Example: H7/g6 on Ø30 mm

This is the CLASSIC general-purpose fit — “clearance fit for general machine construction”. What does this mean in practice?

The hole Ø30 H7:

  • Look up Ø30 in the ISO 286-2 table.
  • H7 column: +0.021/0 mm.
  • Final tolerance: Ø30.000 mm minimum to Ø30.021 mm maximum.

The shaft Ø30 g6:

  • g6 column for Ø30: -0.007/-0.020 mm.
  • Final tolerance: Ø29.980 mm minimum to Ø29.993 mm maximum.

Combined fit:

  • Minimum clearance: Ø30.000 (hole minimum) − Ø29.993 (shaft maximum) = +7 μm.
  • Maximum clearance: Ø30.021 (hole maximum) − Ø29.980 (shaft minimum) = +41 μm.

This gives H7/g6 a CLEARANCE FIT with 7-41 μm clearance. Good for applications such as oil-lubricated shaft bearings, slow-rotating machine components.

Why the tolerance table is necessary

Without the table, tolerance VALUES cannot be converted from DESIGNATION (H7, g6) to practically usable MEASUREMENT VALUES. Consequences:

  • Toolmakers cannot MEASURE whether a finished component is within tolerance.
  • QC inspectors cannot write correct calibration and verification protocols.
  • Machine programmers cannot set the correct tolerance in the CNC program.
  • Designers cannot select the right fit for new work.

The table CONTAINS:

  • Diameter ranges (0-3 mm, 3-6 mm, 6-10 mm, …, 400-500 mm) for different precision requirements.
  • All standard letter codes (A-ZC for holes, a-zc for shafts).
  • All standard IT grades (IT01 to IT18).
  • Numerical tolerance values in micrometers per diameter range.

Practical use of the table

Standard workflow when interpreting a technical drawing:

  1. Read the drawing: “Ø25 H8/f7”.
  2. Look up the diameter range: 25 mm falls within the range “18 to 30 mm” in the table.
  3. Look up the H8 column in that range: H8 = +33/0 μm.
  4. Look up the f7 column: f7 = -20/-41 μm.
  5. Calculate hole tolerance: Ø25.000 to Ø25.033 mm.
  6. Calculate shaft tolerance: Ø24.959 to Ø24.980 mm.
  7. Total clearance: (25.000 − 24.980) to (25.033 − 24.959) = +20 μm to +74 μm.

Lookup time: 30-60 seconds per complete fit. Without the table: IMPOSSIBLE to verify.

Table structure and format

This tolerance table from Schut is a laminated paper set (typically 3-6 pages) covering:

  • Pages 1-3: HOLE tolerances (letters A-Z). All standard precision grades (IT6, IT7, IT8, IT9, IT10, IT11).
  • Pages 4-6: SHAFT tolerances (letters a-z).
  • Extra: Preferred fits table showing recommended H- and h-based fits for various application types.

Laminated paper format is standard for the toolmaker’s workshop:

  • Withstands oil splashes, coolant spray, hand sweat.
  • Can be wiped clean after use.
  • Physically robust for daily use.
  • No batteries, no electronics — always works.

Alternative format variants

Digital app / smartphone: Many apps exist for ISO 286 lookups. Advantage: searchable, no physical page-flipping. Disadvantage: requires battery, can break, may NOT be permitted in restrictive workshop environments (e.g. cleanrooms, nuclear power inspection).

Built-in CAD software: Solidworks, CATIA, NX have a built-in ISO 286 database. Good for designers during the design phase. Not available on the shop floor.

Paper reference (this one): Standard supplementary tool for the toolmaker’s bench, QC station, calibration lab. Quick lookup without power sources.

Common fit notations and their uses

Fit Type Use
H7/h6 Loose transition Hand-assembled parts
H7/g6 Clearance Slow-rotating lubricated shafts
H7/f7 Clearance Fast-rotating motor shafts
H7/j6 Transition Precision-mounted components, removable
H7/k6 Transition Standard fit for bearing sleeves
H7/n6 Tight transition Fixed bearings, requires mechanical press
H7/p6 Interference Press-fitted joint for permanent assemblies
H7/s6 Strong interference Requires thermal shrink fit (heat hole, cool shaft)

Applications

Toolmaker’s workshop: Daily reference for all precision mechanical work.

Designers and engineers: Quick lookup during design meetings and verification discussions.

QC inspectors: Verifying that measured values fall within the tolerance window.

CNC programmers: Converting drawing notations into CNC tolerance parameters.

Training institutions: Vocational schools and technical colleges use the table to teach students practical metrology.

Calibration labs: Reference for specific calibration tolerances.

Maintenance workshops: Wear diagnosis — comparing actual dimension against original tolerance specification.

Spare parts manufacturing: Production of replacement parts that must fit into existing installations.

Complementary standards

ISO 286-2 is the most important tolerance standard but NOT the only one:

  • ISO 2768: GENERAL tolerances for linear dimensions (fine/medium/coarse — f, m, c).
  • ISO 1101: Geometric tolerancing (straightness, flatness, cylindricity, etc.).
  • ISO 1660: Surface roughness notation.
  • ANSI B4.2: American equivalent to ISO 286.
  • DIN 7715: German national standard (largely ISO 286-compatible).

Complete toolmaker reference libraries include all of these as separate booklets.

Historical context

ISO 286 was developed from the German DIN 7150 (from the 1930s) and became an international standard in 1988. The underlying concepts stem from the Whitworth-France-Germany consensus of the late 1800s.

Revision ISO 286-2:2010 is the current version. Updates occur roughly every 20 years to incorporate new measurement technology and new materials.

Specifications

  • Content: ISO 286-2 tolerance table.
  • Diameter range: up to 500 mm nominal.
  • Tolerances: all standard letter codes (A-Z for holes, a-z for shafts).
  • Precision grades: IT01 to IT18.
  • Format: laminated paper, robust for workshop environments.
  • Size: A4 or larger foldout.
  • Supplied with Schut ECONOMY LINE series branding.

What you get for your money

Schut tolerance table according to ISO 286-2, a complete lookup table for tolerances and fits up to 500 mm nominal diameter, all standard letter codes (A-Z holes, a-z shafts), all precision grades IT01-IT18, laminated durable paper for workshop environments. 533 kr.

The standard reference for toolmakers, designers, QC inspectors, CNC programmers, training institutions, calibration labs and maintenance workshops. The premium over “no table” is minimal, and for any business reading technical drawings with ISO 286 notations, this table is INDISPENSABLE — without it, all the drawing’s tolerance callouts are just SYMBOLS on paper with no practical meaning.

Read more: ISO 286-2 tolerance table in the shop →